Benshaw Molded Case Circuit Breakers are designed to provide both overload and short-circuit protection for industrial electrical equipment. Available in seven different compact frame sizes, Benshaw’s line of circuit breakers offer a safe, reliable solution for applications ranging from 15 to 1200 amps.
Electronic Trip Circuit Breakers
Browse available products below … or use the menu on the left to drill into this category.
Thermal Magnetic Circuit Breakers
Browse available products below … or use the menu on the left to drill into this category.
Circuit Breaker 15 A – 100 Frame 3P 600 VAC, H-High Fault, FTU Trip Unit, 65 KAIC Interrupt at 480 VAC$348.40Extended Part No: R2CB-15A-100F-3P-HF-FTU Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware. Continue Reading Circuit Breaker 15 A – 100 Frame 3P 600 VAC, H-High Fault, FTU Trip Unit, 65 KAIC Interrupt at 480 VAC
Circuit Breaker 40 A – 150 Frame 3P 600 VAC, N-Normal Fault, FTU Trip Unit, 35 KAIC Interrupt at 480 VAC$364.65Extended Part No: R2CB-40A-150F-3P-NF-FTU Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware. Continue Reading Circuit Breaker 40 A – 150 Frame 3P 600 VAC, N-Normal Fault, FTU Trip Unit, 35 KAIC Interrupt at 480 VAC
Circuit Breaker 50 A – 150 Frame 3P 600 VAC, N-Normal Fault, FTU Trip Unit, 35 KAIC Interrupt at 480 VAC$364.65Extended Part No: R2CB-50A-150F-3P-NF-FTU Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware. Continue Reading Circuit Breaker 50 A – 150 Frame 3P 600 VAC, N-Normal Fault, FTU Trip Unit, 35 KAIC Interrupt at 480 VAC
Circuit Breaker 100 A – 150 Frame 3P 600 VAC, N-Normal Fault, FTU Trip Unit, 35 KAIC Interrupt at 480 VAC$364.65Extended Part No: R2CB-100A-150F-3P-NF-FTU Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware. Continue Reading Circuit Breaker 100 A – 150 Frame 3P 600 VAC, N-Normal Fault, FTU Trip Unit, 35 KAIC Interrupt at 480 VAC
Circuit Breaker 60 A – 150 Frame 3P 600 VAC, N-Normal Fault, FTU Trip Unit, 35 KAIC Interrupt at 480 VAC$401.05Extended Part No: R2CB-60A-150F-3P-NF-FTU Three pole, fixed thermal and fixed magnet, 600 volt rated circuit breaker. Includes line and load lugs and mounting hardware. Continue Reading Circuit Breaker 60 A – 150 Frame 3P 600 VAC, N-Normal Fault, FTU Trip Unit, 35 KAIC Interrupt at 480 VAC
Need help finding the circuit breaker(s) you need? Get in touch!

